LeafMed Technology

LeafPure Duo / Solo- The Pure Q-switched Laser Solution

LeafPure-Duo / Solo is for a broad range of indications to maximize your practice potential with an option for all skin types. Q-Switched Nd:YAG laser features proven PhotoAcoustic Technology and multiple modes for efficient, reproducible results. Proven Q-Switched technology enables fast tattoo removal treatment of all colors on all skin types, plus a broad range of additional applications. Three modes (1064 nm, 532nm) enable treatment of all pigment and skin revitalization options.


 

Advanced technology design ensure excellent laser beam;
Proprietary PhotoAcoustic Technology Pulse (PTP);
Three output modes;

Brief Introduction

Superior and Proven Reliability

Integrated Handpiece communicates directly with the laser for faster and precise treatments. Constant aiming beam intensity allows for more precise treatments as beam diameter changes.

Enhanced Versatility and Unlimited Potential

LeafPure-Duo is for a broad range of indications to maximize your practice potential with an option for all skin types. Q-Switched Nd:YAG laser features proven PhotoAcoustic Technology

and multiple modes for efficient, reproducible results. 

Proven Q-Switched technology enables fast tattoo removal treatment of all colors on all skin types, plus a broad range of additional applications. Three modes (1064 nm, 532nm) enable

treatment of all pigment and skin revitalization options.

Tattoo Removal ; Epidermal and Dermal Pigment ; Skin Resurfacing ; Melasma ; Vascular lesions

High power, Safe and Comfort

High peak power, and short pulse duration result in PhotoAcoustic action to shatter the target chromophore while minimizing harm to surrounding tissue.

True flat-top beam profile delivers high energy evenly over the skin’s surface significantly reducing potential side-effects.

New, modern Graphic User Interface (GUI) is extremely easy to use, reducing treatment and prep time with convenient pre-sets and enhanced customization.

Auto Calibration

Possible to do stable treatment with constant energy.

Easy after sale maintenance.

Advanced Technology Design

Utilized more technologies ensure excellent laser beam

Enhanced treatment safety due to avoidance of bulk heating using the homogenizer • Top-hat beam profile minimizes epidermal damage, tissue textural changes and the occurrence of scarring • A lack of an homogenizer might result in hot spots within the beam and increased risk of scarring.

By inserting a diffractive optical element (DOE) into the laser resonator, the output of the laser is converted from a single Gaussian mode or a near-Gaussian mode to a super-Gaussian mode output, thereby homogenizing the output spot and avoiding the middle strong and surrounding weak, or annular distribution etc. uneven condition.

The conventional outputs of Q-switched lasers and sub-nanosecond lasers are linearly polarized light. Linearly polarized light has different optical properties in different directions, which is not conducive to stable and consistent treatment and harmful on laser protection (such as the change of the shape and intensity of the light spot with the rotation of the arm and handpiece, etc.). At the output end, the linearly polarized light is restored to circularly polarized light by an optical element, which is beneficial to eliminate these adverse effects.

Homogeneous flat-top beam profile is free of hot spots. Consistent depth of penetration for predictable results.

In the Q switch mode, the IGBT discharge is used to control the xenon lamp to emit light. The Q switch is only turned on after the xenon lamp is extinguished, so that the output light is only a Q-switched laser with high peak power (commonly known as dynamic light), and eliminates the output of static light, which is conventional relaxation oscillation laser with the ineffective ness and thermal response to pigments. This way improves the therapeutic effect, reduces side effects, and improves the laser efficiency, low-carbon energy saving (about 26% energy saving), and is conducive to the continuous operation of the equipment and prolongs the lifespan

Integrated design of laser and optical transmission system (light guide arm, handle, etc.), integrated optimization, so as to achieve the optimal system (beam quality, spot uniformity, energy stability, lifespan, etc.).

Proprietary PhotoAcoustic Technology Pulse (PTP)

Double pulse mode of PTP enables delivery of maximum fluence vs. A single pulse. The microsecond lapse between pulses enables delivery of high energy for improved results while enhancing patient comfort.

Three output modes:

Single Pulse mode(Q-Switch): Q-switched pulse output, output a Q-switched laser pulse per

shot, used for pigment therapy

Clinical Photos

LeafPure-Duo/LeafPure-Solo Specification:

Laser Type
Nd:YAG   /   SHG Nd:YAG
Wavelength
1064nm  /  532nm
Max. Energy(Duo)
1200mj   / 600mj
Peak Power(Duo)>200MW    /  >100MW
Max. Energy(Solo)800mj   / 400mj
Peak Power(Solo)>140MW    /  >70MW
Repetition Rate
1-10 Hz (1-7Hz@PTP Mode )
Spot Sizes2-10mm
Delivery System
Articulated Arm with Zoom handpiece
User Interface
10.1-inch FHD TP
Mainframe Size816(L)*360(W)*740(H)mm
Arm Size750(L)*50(W)*150(H)mm
Weight90KG
Power Requirments1200W

We are actively looking for Distributors and Dealers, more favorable prices, and discounts. If interested, contact us soon